Warm Welcome

::::::::::::::::Praise The Lord:::::::::::::::::

Get Everything On Amazon !

Showing posts with label Protective relay. Show all posts
Showing posts with label Protective relay. Show all posts

The art and science of protective relaying

File Size : 2.82MB


Pages:-357 pages



  • 1. The philosophy of protective relaying


    What is protective relaying?


    The function of protective relaying


    Fundamental principles of protective relaying


    - primary relaying


    - back-up relaying


    - protection against other abnormal conditions


    Functional characteristics of protective relaying


    - sensitivity, selectivity, and speed


    - reliability


    How do protective relays operate?

  • 2. Fundamental relay-operating principles and characteristics


    General considerations


    - operating principles


    - definitions of operation


    - operation indicators


    - seal-in and holding coils, and seal-in relays


    - adjustment of pickup or reset


    - time delay and its definitions


    Single-quantity relays of the electromagnetic-attraction type


    - operating principle


    - ratio of reset to pickup


    - tendency toward vibration


    Directional relays of the electromagnetic attraction type


    - operating principle


    - efficiency


    - ratio of continuous thermal capacity to pickup


    Induction-type relays-general operating principles


    - the production of actuating force


    - types of actuating structure

  • Single-quantity induction relays


    - torque control


    - effect of frequency


    - effect of d-c offset


    - ratio of reset to pickup

  • Directional induction relays


    - torque relations in terms of actuating quantities


    - the significance of the term "directional"


    - the polarizing quantity of a directional relay


    - the operating characteristic of a directional relay


    - the "constant-product" characteristic


    - effect of d-c offset and other transients


    The universal relay-torque equation

  • 3. Current, voltage, directional, current (or voltage)-balance, and differential relays


    General protective-relay features


    Overcurrent, undercurrent, overvoltage, and undervoltage relays


    D-C directional relays


    A-C directional relays


    Current (or voltage) - balance relays


    Differential relays

  • 4. Distance relays


    The impedance-type distance relay


    The modified impedance-type distance relay


    The reactance-type distance relay


    The mho-type distance relay


    General considerations applicable to all distance relays

  • 5. Wire-pilot relays


    Why current-differential relaying is not used


    Purpose of a pilot


    Tripping and blocking pilots


    D-C wire-pilot relaying


    Additional fundamental considerations


    A-C wire-pilot relaying

  • 6. Carrier-current-pilot and microwave-pilot relays


    The carrier-current pilot


    The microwave pilot


    Phase-comparison relaying


    Directional-comparison relaying


    Looking ahead

  • 7. Current transformers


    Types of current transformers


    Calculation of ct accuracy


    Polarity and connections

  • 8. Voltage transformers


    Accuracy of potential transformers


    Capacitance potential devices


    The use of low-tension voltage


    Polarity and connections

  • 9. Methods for analyzing generalizing, and visualizing relay response


    The R-X diagram


    Short circuits


    Power swings and loss of synchronism


    Response of polyphase directional relays to positive- and negative-phase-sequence volt-amperes


    Response of single-phase directional relays to short circuits


    Phase-sequence filters

  • 10 A-C generator and motor protection


    Generator protection

  • 11. Transformer protection


    Power transformers and power autotransformers


    Step voltage regulators


    Grounding transformers


    Electric arc-furnace transformers


    Power-rectifier transformers

  • 12 bus protection


    Protection by back-up relays


    The fault bus1


    Directional-comparison relaying


    Current-differential relaying with overcurrent relays


    Partial-differential relaying


    Current-differential relaying with percentage-differential relays


    Voltage-differential relaying with "linear couplers"


    Current-differential relaying with overvoltage relays


    Combined power-transformer and bus protection


    The value of bus sectionalizing


    Back-up protection for bus faults


    Grounding the secondaries of differentially connected ct's


    Once-a-shift testing of differential-relaying equipment

  • 13. Line protection with overcurrent relays


    How to set inverse-time-overcurrent relays for coordination


    Arc and ground resistance


    Effect of loop circuits on overcurrent relay adjustments


    Effect of system on choice of inverseness of relay characteristic


    The use of instantaneous overcurrent relays


    An incidental advantage of instantaneous overcurrent relaying


    Overreach of instantaneous overcurrent relays


    The directional feature


    Use of two versus three relays for phase-fault protection


    Single-phase versus polyphase directional-overcurrent relays


    How to prevent single-phase directional overcurrent-relay misoperation during ground faults


    Adjustment of ground versus phase relays


    Effect of limiting the magnitude of ground-fault current


    Transient ct errors


    Detection of ground faults in ungrounded systems


    Effect of ground-fault neutralizers on line relaying


    The effect of open phases not accompanied by a short circuit


    The effect of open phases accompanied by short circuits


    Polarizing the directional units of ground relays


    Negative-phase-sequence directional units for ground-fault relaying


    Current-balance and power-balance relaying


    Automatic reclosing


    Restoration of service to distribution feeders after prolonged outages


    Coordinating with fuses


    A-C and capacitor tripping

  • 14. Line protection with distance relays


    The choice between impedance, reactance, or mho


    The adjustment of distance relays


    The effect of arcs on distance-relay operation


    The effect of intermediate current sources on distance-relay operation


    Overreach because of offset current waves


    Overreach of ground distance relays for phase faults


    Use of low-tension voltage


    Use of low-tension current


    Effect of power-transformer magnetizing-current inrush on distance-relay operation


    The connections of ground distance relays


    Operation when PT fuses blow


    Purposeful tripping on loss of synchronism


    Blocking tripping on loss of synchronism


    Automatic reclosing


    Effect of presence of expulsion protective gaps


    Effect of a series capacitor


    Cost-reduction schemes for distance relaying


    Electronic distance relays

  • 15. Line protection with pilot relays


    Wire-pilot relaying


    Obtaining adequate sensitivity


    The protection of multiterminal lines


    Current-transformer requirements


    Back-up protection


    Carrier-current-pilot relaying


    Phase comparison


    Directional comparison


    Combined phase and directional comparison


    All-electronic directional-comparison equipment


    High-speed reclosing

Interior Electrical Systems

File Type:- pdf


File Size:- 1.78 MB


Pages:- 279 pages




Contents:-



  • 1. General

  • 1-1 PURPOSE


    1-2 SCOPE


    1-3 REFERENCES


    1-4 CODES AND STANDARDS


    1-5 SYMBOLS


    1-6 APPLICABILITY


    1-7 MANUAL CONTENT AND ORGANIZATION

  • PRELIMINARY AND DETAILED DESIGN ANALYSIS


    2-1 PRELIMINARY DESIGN


    2-1.1 Principal Points of Contact


    2-1.2 Preliminary Design Guidance for Interior Electrical Systems


    2-1.3 Unified Facilities Guide Specifications


    2-2 ELECTRICAL LOAD CRITERIA


    2-3 OVERVIEW OF DETAILED ANALYSIS CRITERIA


    2-4 SHORT CIRCUIT ANALYSIS


    2-4.1 Analysis and Equipment Criteria


    2-4.2 Short Circuit Sources


    2-4.3 Symmetrical Versus Asymmetrical Current


    2-4.4 Short Circuit Calculations


    2-5 POWER FLOW ANALYSIS


    2-6 VOLTAGE DROP ANALYSIS


    2-6.1 Voltage Drop Calculations


    2-6.2 Motor Starting Studies


    2-7 ELECTRICAL COORDINATION


    2-8 POWER QUALITY AND HARMONIC DISTORTION


    2-9 LIGHTING


    2-10 ENERGY ANALYSIS


    2-10.1 Overview


    2-10.2 New Facility Criteria


    2-10.3 Existing Facilities


    2-10.4 Energy Efficiency Design Opportunities in the Electrical System


    2-11 LIFE-CYCLE COST ANALYSIS


    2-12 ELECTRICAL DRAWINGS


    2-12.1 Introduction


    2-12.2 One-Line Diagrams


    2-12.3 Switchgear Lineups


    2-12.4 MCC Layouts


    2-12.5 Grounding


    2-12.6 Control Panel Wiring Diagrams


    2-12.7 Control Schematics


    2-12.8 Miscellaneous Interconnection Diagrams


    2-12.9 Equipment Layouts with Conduit or Cable Tray


    2-12.10 Panel Schedules


    2-12.11 Lighting and Receptacle Layouts


    2-12.12 Motor List


    2-12.13 Conduit or Cable Schedule

  • GENERAL POWER SYSTEM CRITERIA


    3-1 CHARACTERISTICS


    3-1.1 Voltage


    3-1.2 Frequency


    3-1.3 Power Factor


    3-1.4 Neutral Conductor Grounding


    3-2 NORMAL POWER SOURCE


    3-3 ALTERNATE AND BACKUP POWER SOURCE


    3-4 SERVICES

  • POWER DISTRIBUTION AND UTILIZATION-TRANSFORMERS


    4-1 RATINGS


    4-1.1 Introduction


    4-1.2 Voltage and Current


    4-1.3 Temperature and kVA


    4-1.4 Impedance


    4-1.5 Number of Phases


    4-1.6 Transformer Taps


    4-1.7 Noise


    4-1.8 Basic Impulse Insulation Levels (BILs)


    4-2 LOW VOLTAGE TRANSFORMERS


    4-3 MEDIUM VOLTAGE TRANSFORMERS


    4-4 OTHER TRANSFORMERS


    4-4.1 Isolation Transformers


    4-4.2 Buck-Boost Transformers


    4-4.3 K-Factor Transformers


    4-4.4 Specialty Transformers


    4-5 TRANSFORMER INSTALLATION CRITERIA


    4-5.1 Introduction


    4-5.2 Dry-Type Transformers


    4-5.3 Less-Flammable, Liquid-Insulated, and Oil-Insulated Transformers


    4-5.4 Fire Protection Criteria


    4-6 TRANSFORMER SIZING


    4-7 INFORMATION SOURCES

  • CHAPTER 5 POWER DISTRIBUTION AND UTILIZATION-SWITCHGEAR, LOAD CENTERS, AND BREAKERS

  • 5-1 SERVICE ENTRANCE


    5-2 SWITCHGEAR AND SWITCHBOARDS GENERAL CRITERIA


    5-3 HIGH VOLTAGE SWITCHGEAR


    5-4 MEDIUM VOLTAGE SWITCHGEAR


    5-4.1 Ratings


    5-4.2 Low Voltage Conductors in Medium Voltage Switchgear


    5-5 LOW VOLTAGE BREAKERS AND PANELS


    5-6 MOTOR CONTROL CENTERS


    5-7 DISCONNECT SWITCHES


    5-8 CIRCUIT LOCKOUT REQUIREMENTS


    5-9 INFORMATION SOURCES

  • CHAPTER 6 POWER DISTRIBUTION AND UTILIZATION-RACEWAY AND WIRING

  • 6-1 RACEWAY CRITERIA


    6-2 WIRING SYSTEM CRITERIA


    6-3 SIZING WIRING SYSTEMS FOR ENERGY SAVINGS


    6-4 CONVENIENCE OUTLETS AND RECEPTACLES


    6-5 WIRING FOR TEMPORARY POWER AND LIGHTING


    6-6 ACCEPTANCE TESTING OF WIRING SYSTEMS

  • CHAPTER 7 POWER DISTRIBUTION AND UTILIZATION-MOTORS AND MOTOR CONTROL CIRCUITS

  • 7-1 BASIC MOTOR CRITERIA


    7-2 MOTOR CONTROL CIRCUITS


    7-3 ADJUSTABLE SPEED DRIVES

  • CHAPTER 8 POWER DISTRIBUTION AND UTILIZATION-OTHER DESIGN CRITERIA

  • 8-1 ELECTRICAL EQUIPMENT CLEARANCES AND GUARDS


    8-1.1 Background


    8-1.2 Equipment Rated 600 Volts and Lower


    8-1.3 Equipment Rated Above 600 Volts


    8-2 ENCLOSURES


    8-3 HAZARDOUS LOCATIONS


    8-4 400-HERTZ DISTRIBUTION SYSTEMS


    8-5 METERING


    8-6 POWER FACTOR CORRECTION

  • CHAPTER 9 ELECTRICAL SYSTEM PROTECTION AND COORDINATION

  • 9-1 PROTECTION SYSTEM DESIGN


    9-2 ELECTRICAL COORDINATION ANALYSIS CRITERIA


    9-2.1 Introduction


    9-2.2 Coordination Study Description


    9-2.3 Coordination Time Intervals


    9-2.4 Pickup Current


    9-2.5 Coordination Curves


    9-2.6 Coordination Analysis


    9-2.7 Coordination Study Report


    9-3 PROTECTIVE RELAYS


    9-4 INSTRUMENT TRANSFORMERS


    9-4.1 Background


    9-4.2 Current Transformers


    9-4.3 Potential Transformers


    9-5 FUSES


    9-6 OVERLOAD RELAYS


    9-7 CIRCUIT BREAKERS


    9-8 PROTECTIVE DEVICE DESIGNATIONS


    9-9 INFORMATION SOURCES

  • CHAPTER 10 GROUNDING, BONDING, AND LIGHTNING PROTECTION

  • 10-1 INTRODUCTION


    10-2 NEC GROUNDING AND BONDING REQUIREMENTS


    10-3 STATIC PROTECTION


    10-4 COMMUNICATIONS SYSTEMS GROUNDING AND BONDING


    10-4.1 Introduction


    10-4.2 Connection to the Grounding Electrode


    10-4.3 Commercial Building Grounding and Bonding Requirements for Telecommunications


    10-5 LIGHTNING PROTECTION


    10-6 INFORMATION SOURCES

  • CHAPTER 11 SURGE PROTECTION

  • 11-1 INTRODUCTION


    11-2 SURGE PROTECTION DESIGN


    11-2.1 Parallel Versus Series Approach


    11-2.2 Multiple Layer Protection Design


    11-3 INSTALLATION CRITERIA


    11-3.1 Minimizing Lead Length for Parallel Surge Protectors


    11-3.2 Breaker Connection


    11-3.3 Grounding


    11-3.4 Acceptance Tests


    11-3.5 Periodic Maintenance


    11-4 SURGE PROTECTION FOR COMMUNICATIONS AND RELATED SYSTEMS

  • CHAPTER 12 POWER SYSTEM QUALITY

  • 12-1 INTRODUCTION


    12-2 UNBALANCED VOLTAGES


    12-3 HARMONIC DISTORTION EVALUATION


    12-4 HARMONIC CURRENT EFFECTS ON TRANSFORMERS


    12-5 POWER QUALITY DESIGN


    12-6 NONLINEAR LOAD DESIGN CONSIDERATIONS


    12-7 NEUTRAL CIRCUIT SIZING FOR NONLINEAR LOADS


    12-7.1 Potential Neutral Current Magnitudes


    12-7.2 Installation Design Criteria


    12-8 INFORMATION SOURCES

  • CHAPTER 13 EMERGENCY AND STANDBY POWER SYSTEMS

  • 13-1 ESTABLISHING THE NEED FOR BACKUP POWER


    13-2 CLASSIFYING EMERGENCY POWER LOADS


    13-3 ENGINE GENERATORS


    13-4 UPS SYSTEMS


    13-4.1 Introduction


    13-4.2 Selection and Performance


    13-4.3 Sizing


    13-4.4 Selection of a Large UPS System or Multiple Smaller UPS Systems

  • 13-4.5 Design Criteria


    13-4.6 Site Survey for an Installation


    13-5 AUTOMATIC TRANSFER EQUIPMENT


    13-5.1 Introduction


    13-5.2 Transfer Methods


    13-5.3 Design Considerations


    13-5.4 Static Transfer Switches


    13-5.5 Sizing


    13-5.6 Effect of Motor Loads


    13-5.7 Maintaining Ground Fault Protection


    13-5.8 Additional System Design Considerations


    13-5.9 Information Sources

  • CHAPTER 14 STATIONARY BATTERY SYSTEMS

  • 14-1 STATIONARY BATTERIES


    14-1.1 Selection


    14-1.2 Battery Areas and Battery Racks


    14-1.3 Installation Design Considerations


    14-2 BATTERY CHARGERS


    14-3 BATTERY PROTECTION

  • CHAPTER 15 LIGHTING

  • 15-1 LIGHTING DESIGN CRITERIA

  • CHAPTER 16 COMMUNICATIONS AND INFORMATION SYSTEMS

  • 16-1 INTRODUCTION


    16-2 ARMY DESIGN CRITERIA


    16-3 NAVY DESIGN CRITERIA


    16-4 AIR FORCE DESIGN CRITERIA

  • CHAPTER 17 AUXILIARY SYSTEMS

  • 17-1 FIRE ALARM AND DETECTION SYSTEMS


    17-2 SECURITY SYSTEMS


    17-3 TELEVISION SYSTEMS


    17-4 CLOCK SYSTEMS


    17-5 ENERGY MANAGEMENT AND CONTROL SYSTEMS

  • CHAPTER 18 FACILITY-SPECIFIC DESIGN CRITERIA

  • 18-1 MEDICAL FACILITIES


    18-2 POWER DISTRIBUTION FOR AIRCRAFT HANGARS (SHELTERS)


    18-3 HIGH-ALTITUDE ELECTROMAGNETIC PULSE (HEMP) AND TEMPEST PROTECTION


    18-4 SEISMICALLY QUALIFIED DESIGNS


    18-5 TROPICAL ENGINEERING


    18-6 ARCTIC ENGINEERING


    18-7 GENERAL FACILITY TYPES

Inside Catalogs

Twitter Delicious Facebook Digg Stumbleupon Favorites More

 
Design by Tej Enosh | Maintained by Teja labs San Fsc.inc - We Like Thums Up | And Coca-Cola